Filtrar :
Norma o proyecto bajo la responsabilidad directa de ISO/TC 138/SC 1 Secretaría | Etapa | ICS |
---|---|---|
Pipes and fittings of plastics materials — Fittings for domestic and industrial waste pipes — Basic dimensions: Metric series — Part 1: Unplasticized poly(vinyl chloride) (PVC-U)
|
90.93 | |
Unplasticized poly(vinyl chloride) (PVC-U) pipes and fittings for soil and waste discharge (low and high temperature) systems inside buildings — Specifications
|
95.99 | |
Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings — Unplasticized poly(vinyl chloride) (PVC-U)
|
90.93 | |
Unplasticized poly(vinyl chloride) (PVC-U) pipes and fittings for buried drainage and sewerage systems — Specifications
|
95.99 | |
Plastics piping systems for non-pressure underground drainage and sewerage — Unplasticized poly(vinyl chloride) (PVC-U)
|
90.93 | |
Plastics piping systems for non-pressure underground conveyance and storage of non-potable water — Boxes used for retention, detention, storage and transportation systems — Specifications for storm water boxes made of PE, PP and PVC-U
|
60.60 | |
Plastics piping systems for non-pressure underground conveyance and storage of non-potable water — Arch-shaped, corrugated wall chambers made of PE or PP used for retention, detention, storage and transportation of storm water systems — Product specifications and performance criteria
|
60.60 | |
Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings — Thermoplastics — Recommended practice for installation
|
90.93 | |
Above-ground drainage — Recommended practice and techniques for the installation of unplasticized polyvinyl chloride (PVC-U) sanitary pipework for above-ground systems inside buildings
|
95.99 | |
Recommended techniques for the installation of unplasticized poly(vinyl chloride) (PVC-U) buried drains and sewers
|
95.99 | |
Performance requirements for plastics pipes and fittings for use in underground drainage and sewage
|
95.99 | |
Polypropylene (PP) pipes and fittings (jointed by means of elastomeric sealing rings) for soil and waste discharge (low and high temperature) systems inside buildings — Specifications
|
95.99 | |
Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings — Polypropylene (PP)
|
90.20 | |
Chlorinated poly(vinyl chloride) (PVC-C) pipes and fittings for soil and waste discharge (low and high temperature) systems inside buildings — Specifications
|
95.99 | |
Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings — Chlorinated poly(vinyl chloride) (PVC-C)
|
90.93 | |
Acrylonitrile/butadiene/styrene (ABS) pipes and fittings for soil and waste discharge (low and high temperature) systems inside buildings — Specifications
|
95.99 | |
Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings — Acrylonitrile-butadiene-styrene (ABS)
|
90.20 | |
Plastics pipes and fittings — Dimensions of sockets and spigots for discharge systems inside buildings — Part 1: Unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly (vinyl chloride) (PVC-C)
|
90.93 | |
Plastics pipes and fittings — Dimensions of sockets and spigots for discharge systems inside buildings — Part 2: Polyethylene (PE)
|
90.20 | |
Plastics pipes and fittings — Dimensions of sockets and spigots for discharge systems inside buildings — Part 3: Polypropylene (PP)
|
90.93 | |
Plastics pipes and fittings — Dimensions of sockets and spigots for discharge systems inside buildings — Part 4: Acrylonitrile/butadiene/styrene (ABS)
|
90.20 | |
High-density polyethylene (PE-HD) pipes and fittings for soil and waste discharge (low and high temperature) systems inside buildings — Specifications
|
95.99 | |
Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings — Polyethylene (PE)
|
90.93 | |
High-density polyethylene (PE-HD) pipes and fittings for buried drainage and sewerage systems — Specifications
|
95.99 | |
Plastics piping systems for non-pressure underground drainage and sewerage — Polyethylene (PE)
|
90.93 | |
Polypropylene (PP) pipes and fittings for buried drainage and sewerage systems — Specifications
|
95.99 | |
Plastics piping systems for non-pressure underground drainage and sewerage — Polypropylene (PP)
|
90.93 | |
Plastics traps for discharge pipework systems inside buildings
|
90.93 | |
Thermoplastics piping systems for non-pressure applications — Unplasticized poly(vinyl chloride) (PVC-U) pipes and fittings — Determination of the viscosity number and K-value
|
90.93 | |
Thermoplastics piping systems for non-pressure applications — Test method for watertightness
|
90.93 | |
Thermoplastics piping systems for soil and waste discharge inside buildings — Test method for airtightness of joints
|
90.93 | |
Thermoplastics piping systems for non-pressure applications — Test method for resistance to elevated temperature cycling
|
95.99 | |
Thermoplastics piping systems for non-pressure applications — Test method for resistance to elevated temperature cycling
|
90.93 | |
Thermoplastics piping systems for underground non-pressure applications — Test method for leaktightness of elastomeric sealing ring type joints
|
95.99 | |
Thermoplastics piping systems for underground non-pressure applications — Test method for leaktightness of elastomeric sealing ring type joints
|
95.99 | |
Thermoplastics piping systems for underground non-pressure applications — Test method for leaktightness of elastomeric sealing ring type joints
|
60.60 | |
Thermoplastics piping systems for non-pressure underground drainage and sewerage — Test method for resistance to combined temperature cycling and external loading
|
90.93 | |
Thermoplastics piping systems for non-pressure underground drainage and sewerage — Test method for resistance to combined temperature cycling and external loading — Amendment 1
|
60.60 | |
Thermoplastics piping systems for non-pressure underground drainage and sewerage — Thermoplastics spirally-formed structured-wall pipes — Determination of the tensile strength of a seam
|
90.93 | |
Thermoplastics piping systems for non-pressure underground drainage and sewerage — Thermoplastics fittings — Test method for impact strength
|
90.93 | |
Thermoplastics piping systems for non-pressure underground drainage and sewerage — Thermoplastics fittings — Test method for mechanical strength or flexibility of fabricated fittings
|
90.93 | |
Thermoplastics piping systems for non-pressure underground drainage and sewerage — Joints for buried non-pressure applications — Test method for the long-term sealing performance of joints with elastomeric seals by estimating the sealing pressure
|
95.99 | |
Thermoplastics piping systems for non-pressure underground drainage and sewerage — Joints for buried non-pressure applications — Test method for the long-term sealing performance of joints with elastomeric seals by estimating the sealing pressure
|
60.60 | |
Thermoplastics piping systems for non-pressure underground drainage and sewerage — Thermoplastics shafts or risers for inspection chambers and manholes — Determination of resistance against surface and traffic loading
|
95.99 | |
Thermoplastics piping systems for non-pressure underground drainage and sewerage — Thermoplastics shafts or risers for inspection chambers and manholes — Determination of resistance against surface and traffic loading
|
60.60 | |
Thermoplastics piping systems for non-pressure underground drainage and sewerage — Thermoplastics inspection chamber and manhole bases — Test methods for buckling resistance
|
95.99 | |
Thermoplastics piping systems for non-pressure underground drainage and sewerage — Thermoplastics inspection chamber and manhole bases — Test methods for buckling resistance
|
60.60 | |
Thermoplastics piping systems for non-pressure underground drainage and sewerage — Thermoplastics shafts or risers for inspection chambers and manholes — Determination of ring stiffness
|
95.99 | |
Thermoplastics piping systems for non-pressure underground drainage and sewerage — Thermoplastics shafts or risers for inspection chambers and manholes — Determination of ring stiffness
|
60.60 | |
Plastics piping systems for non-pressure underground drainage and sewerage — Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP), polypropylene with mineral modifiers (PP-MD) and polyethylene (PE) — Specifications for manholes and inspection chambers in traffic areas and underground installations
|
90.92 | |
Plastics piping systems for non-pressure underground drainage and sewerage — Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP), polypropylene with mineral modifiers (PP-MD) and polyethylene (PE) — Specifications for manholes and inspection chambers in traffic areas and underground installations
|
40.00 | |
Specifications for thermoplastics covers and frames for manholes and inspection chambers used in non-traffic areas
|
90.93 | |
Wrapped electrofoaming joints for polyethylene (PE) piping systems with smooth outer wall for gravity drains and sewers
|
90.93 | |
Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings — Styrene copolymer blends (SAN + PVC)
|
95.99 | |
Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings — Styrene copolymer blends (SAN + PVC)
|
60.60 | |
Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Part 1: Material specifications and performance criteria for pipes, fittings and system
|
95.99 | |
Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Part 1: Material specification and performance criteria for pipes, fittings and systems
|
60.60 | |
Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Part 2: Pipes and fittings with smooth external surface, Type A
|
95.99 | |
Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Part 2: Pipes and fittings with smooth external surface, Type A
|
60.60 | |
Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Part 3: Pipes and fittings with non-smooth external surface, Type B
|
95.99 | |
Plastics piping systems for non-pressure underground drainage and sewerage — Structured-wall piping systems of unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) — Part 3: Pipes and fittings with non-smooth external surface, Type B
|
60.60 | |
Thermoplastics piping systems for non-pressure underground drainage and sewerage — Test method for the determination of the stress crack resistance of structured-wall polyethylene (PE) pipe materials with recyclates using Un-notched Constant Ligament Stress (UCLS) test
|
20.00 |
|
No se ha encontrado ningún registro que coincida. Pruebe a cambiar los ajustes de filtro.