Resumen
ISO 20492:2008 establishes two methods for testing the resistance to fogging of pre-assembled, permanently sealed insulating glass units or insulating glass units with capillary tubes intentionally left open. The two methods are designated as approach 1 for markets such as North America, and approach 2 for markets such as Europe.
ISO 20492:2008 is not applicable to sealed, insulating glass units containing a spandrel glass coating due to testing limitations.
ISO 20492:2008 does not apply to insulating glass (IG) units whose function is decorative only.
Informaciones generales
-
Estado: PublicadoFecha de publicación: 2008-10Etapa: Norma Internacional para revisar [90.92]
-
Edición: 1Número de páginas: 13
-
Comité Técnico :ISO/TC 160ICS :81.040.20
- RSS actualizaciones
Ciclo de vida
-
Ahora
-
Será reemplazada por
En desarrolloISO/CD 20492-2
EliminadoISO/DIS 20492-2