Abstract
This document specifies an automatic particle counting procedure for determining the number and sizes of particles present in hydraulic-fluid bottle samples of clear, homogeneous, single-phase liquids using an automatic particle counter (APC) that works on the light-extinction principle.
This document is applicable to the monitoring of:
a) the cleanliness level of fluids circulating in hydraulic systems;
b) the progress of a flushing operation;
c) the cleanliness level of support equipment and test rigs;
d) the cleanliness level of packaged stock fluid.
NOTE Measurements can be made with particles suspended in the original liquid or in a sample of the liquid diluted with a compatible liquid when APC coincidence error limits are exceeded.
General information
-
Status: PublishedPublication date: 2022-12Stage: International Standard published [60.60]
-
Edition: 3Number of pages: 20
-
Technical Committee :ISO/TC 131/SC 6ICS :23.100.60
- RSS updates
Life cycle
-
Previously
WithdrawnISO 11500:2008
-
Now
-
00
Preliminary
-
10
Proposal
-
20
Preparatory
-
30
Committee
-
40
Enquiry
-
50
Approval
-
60
Publication
-
90
Review
-
95
Withdrawal
Amendments
Provide additional content; available for purchase; not included in the text of the existing standard.Under developmentISO 11500:2022/WD Amd 1
-
00